On Shear Connection Design in Composite Beams
On Shear Connection Design in Composite Beams
Author(s): Jan Bujnak, Kazimierz Furtak, Jaroslav OdrobinakSubject(s): Methodology and research technology
Published by: Žilinská univerzita v Žilině
Keywords: concrete pressure strength; composite beams;
Summary/Abstract: The paper deals with a way of determining concrete pressure strength when calculating load carrying capacity of steel perfobond strip connectors. This type of strip connectors has been used in composite bridges only recently and no precise methods of calculating them have been worked out so far. The effect of axial forces on bearing capacity of classical stud shear connectors is also given in the paper as a result of research.
Journal: Komunikácie - vedecké listy Žilinskej univerzity v Žiline
- Issue Year: 4/2002
- Issue No: 3
- Page Range: 13-16
- Page Count: 4
- Language: English