Weryfikacja efektu dźwigni w rozciąganym połączeniu
doczołowym sprężonym śrubami
Verification of prying effect in prestressed end-plate connection
Author(s): Krzysztof Ostrowski, Jan Łaguna, Aleksander KozłowskiSubject(s): Architecture
Published by: Biblioteka Politechniki Lubelskiej
Keywords: prestressed end-plate connections; T-stubs; prying effect forces
Summary/Abstract: End-plate connections are very often used is steelwork, as tension and bending connections. As a result of deflection of end plate, additional forces, known as prying forces arise and consequently increase stresses in bolts. Eurocode 1993-1-8 do not distinguish end-plate connections prestressed by high strength bolts from non-prestressed. The aim of the paper is to perform the comparison of previous analytical models and code regulations for coefficient of prying forces to the experimental tests and modelling by finite element method. Results of the analysis show that the behaviour of prestressed connection is essentially different with comparison to non-prestressed.
Journal: Budownictwo i Architektura
- Issue Year: 12/2013
- Issue No: 2
- Page Range: 251-258
- Page Count: 8
- Language: Polish